The Solar Hybrid PCU is an integrated system consisting of a solar charge controller ( MPPT/ PWM ), inverter and a Grid charger. It provides the facility to charge the battery bank through either a Solar or Grid / DG set. The PCU continuously monitors the state of battery voltage, solar power output and the load. Due to sustained usage of power, when the Battery voltage falls below a preset level, the PCU will automatically transfer the load to the Grid power and also charge simultaneously.
Once the batteries are charged to the preset level, the PCU unit cuts off the Grid power from the system and restores it to feeding the loads from the battery bank while also returning to charging the battery from the available solar power. The PCU always gives preference to the solar power and will use Grid power only when the solar power/ battery charge is unable to meet the load requirement.
Brand new SPCU-design from Neulite, where great aesthetics meet reliable performance.
Easy to access control panel and display, convenient wire-routing and groundspace-savings are the prime features of this series.
Time tested and a proven solid performer, the Sunlit Series are Neulite's best selling product till date.
Available in a wide-range of inverter-capacities, you'll find a configuration to meet your power needs!
Model Name | Sunlit 801VA12V1P | Sunlit 102VA24V1P | Sunlit 202VA48V1P | Sunlit 302VA72V1P | Sunlit 502VA120V1P | Sunlit 702VA168V1P | Sunlit 103VA240V1P |
---|---|---|---|---|---|---|---|
Inverter Capacity | 800VA | 1KVA | 2KVA | 3KVA | 5KVA | 7KVA | 10KVA |
Solar Charge Controller | PWM | MPPT | |||||
MPPT Output Voltage | 12VDC | 24VDC | 48VDC | 72VDC | 120VDC | 168VDC | 240VDC |
MPPT Max Current | 20A | 30A | |||||
MPPT Effeciency | >93% | ||||||
Inverter | |||||||
Switching Device | MOSFET/ IGBT | ||||||
Output Voltage | 1 Phase, 230 +/- 5V | ||||||
Output Frequency | 50Hz +/- 1Hz | ||||||
Voltage THD | < 3% | ||||||
Effeciency | >90% @ Normal Load | ||||||
Operating Temperature | -20c to 60c | ||||||
Enclosure Protection | as per IEC IP21 | ||||||
Power Factor | > 0.98 | ||||||
Overload Warning | 105% | ||||||
Overload Cut Off | 110% | ||||||
Protections with alarm | Input Surge, Input Under Voltage, Input Over Voltage, Short Circuit, Battery & Array Reverse Polarity, Heating (Temp. Dependent Fan- Forced Air Cooling) | ||||||
Grid Transfer Voltage | Yes | ||||||
Monitoring | Optional (RS-232) | ||||||
Realtime Clock | Inverter On/Off timer working (Automatic) | No | |||||
No Load Shutdown (Sleep) | < 10 Watts | ||||||
Max Connected Load | 680W @ PF 0.85 | 850W @ PF 0.85 | 1.7KW @ PF 0.85 | 2.55KW @ PF 0.85 | 4.25KW @ PF 0.85 | 5.95KW @ PF 0.85 | 8.5KW @ PF 0.85 |
LCD Display | Inverter On, Mains On, Array On and Array Current, Battery Voltage, Component Temperature, Load %, Battery Charging Indication | ||||||
Grid Charger | |||||||
AC Input | 180VAC-260VAC +/-5VAC, 1 Phase | ||||||
Frequency | 50Hz +/- 1Hz | ||||||
Charging Current | 15 Amps Max Settable |